Review



nattrol respiratory verification panel 2 1  (ZeptoMetrix corporation)


Bioz Verified Symbol ZeptoMetrix corporation is a verified supplier
Bioz Manufacturer Symbol ZeptoMetrix corporation manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    ZeptoMetrix corporation nattrol respiratory verification panel 2 1
    Nattrol Respiratory Verification Panel 2 1, supplied by ZeptoMetrix corporation, used in various techniques. Bioz Stars score: 93/100, based on 30 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nattrol+respiratory+verification+panel+2/NATtrol+Respiratory+Verification+Panel/pmc12844171-237-3-8
    Average 93 stars, based on 30 article reviews
    nattrol respiratory verification panel 2 1 - by Bioz Stars, 2026-10
    93/100 stars

    Images

    Related Articles

    other:

    Article Title: A new system in qualitative RT-PCR detecting SARS-CoV-2 in biological samples: an Italian experience
    Article Snippet: The specificity of the primers and probes was evaluated using ZeptoMetrix panels (ZeptoMetrix, Co.,Buffalo, NY,US): a)SARS-CoV-2 (E/ORF/1ab recombinant) Stock (ZeptoMetric), which is formulated with purified, intact bacterial cells containing synthetic SARS-CoV-2 sequences (the cells have been chemically modified to render them non–infectious and refrigerator stable); b) NATtrolTM Respiratory Verification panel 2 (ZeptoMetrix), which is formulated with purified intact virus particles and bacterial cells that have been chemically modified to render them non-infectious and refrigerator stable; c) NATtrol TM Coronavirus-SARS Stock, containing intact virus particles modified to render them non–infectious and refrigerator stable.

    Article Title: A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection
    Article Snippet: Analytical specificity (ASp) was determined using the NATtrolTM Respiratory Verification Panel 2 (ZeptoMetrix Corporation, New York, United States) containing pathogens causing indistinguishable clinical signs to COVID-19 ( n = 22) and a pool of meningitis encephalitis causative agents ( n = 7) ( ).

    Article Title: Ultrarapid detection of SARS-CoV-2 RNA using a reverse transcription–free exponential amplification reaction, RTF-EXPAR
    Article Snippet: ZeptoMetrix NATtrol Respiratory Verification Panel 2 was used as supplied.

    Article Title: A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection
    Article Snippet: Analytical specificity (ASp) was determined using the NATtrolTM Respiratory Verification Panel 2 (ZeptoMetrix Corporation, New York, United States) containing pathogens causing indistinguishable clinical signs to COVID-19 (n=22) and a pool of meningitis encephalitis causative agents (n=7) ( ).

    Virus:

    Article Title: Development and validation of a multiplex real-time PCR assay for detection and quantification of Streptococcus pneumoniae in pediatric respiratory samples.
    Article Snippet: For cross-reactivity studies against Streptococcus pseudopneumoniae, solutions in sterile water were prepared from plated media of ATCC strain BAA-960 ranging in concentration from 0.5 to 2.0 McFarland standard. .. The NATtrol Respiratory Verification Panel 2 (ZeptoMetrix, Buffalo, NY, USA) was used for crossreactivity studies of molecular material against Mycoplasma pneumoniae, Chlamydo phila pneumoniae, influenza A virus (A/NewCal/20/99, A/Brisbane/10/07, A/NY/02/11), influenza B virus (B/Florida/02/06), rhinovirus, and respiratory syncytial virus A. SARSCoV-2 cross-reactivity was evaluated by using known SARS-CoV-2-positive samples and November/December 2023 Volume 11 Issue 6 10.1128/spectrum.02118-23 3 D ow nl oa de d fr om h ttp s: //j ou rn al s. as m .o rg /jo ur na l/s pe ct ru m o n 04 J an ua ry 2 02 4 by 1 03 .1 63 .2 31 .1 45 . ..

    Article Title: Development and Validation of a Multiplex Real-Time PCR Assay for Detection and Quantification of Streptococcus pneumoniae in Pediatric Respiratory Samples
    Article Snippet: For cross-reactivity studies against Streptococcus. pseudopneumoniae , solutions in sterile water were prepared from plated media of ATCC ® strain BAA-960 ranging in concentration from 0.5 to 2.0 McFarland standard. .. The NATtrol Respiratory Verification Panel 2 (ZeptoMetrix, Buffalo, NY) was used for cross-reactivity studies of molecular material against Mycoplasma pneumoniae, Chlamydophila pneumoniae , influenza A virus (A/NewCal/20/99, A/Brisbane/10/07, A/NY/02/11), influenza B virus (B/Florida/02/06), rhinovirus, and respiratory syncytial virus A. SARS-CoV-2 cross-reactivity was evaluated by using known SARS-CoV-2-positive samples and Exact Diagnostics SARS-CoV-2 standard control material (Exact Diagnostics, Fort Worth, TX, USA). .. Nucleic acid, including internal positive control DNA (ThermoFisher, Waltham, MA, USA), was isolated on Qiagen EZ1 Advanced XL platform using the DNA Tissue Kit (Qiagen, Hilden, Germany) and subjected to real-time PCR analysis on an ABI 7500 real-time PCR system (ThermoFisher, Waltham, MA, USA).

    Article Title: Development and validation of a multiplex real-time PCR assay for detection and quantification of Streptococcus pneumoniae in pediatric respiratory samples
    Article Snippet: For cross-reactivity studies against Streptococcus pseudopneumoniae , solutions in sterile water were prepared from plated media of ATCC strain BAA-960 ranging in concentration from 0.5 to 2.0 McFarland standard. .. The NATtrol Respiratory Verification Panel 2 (ZeptoMetrix, Buffalo, NY, USA) was used for cross-reactivity studies of molecular material against Mycoplasma pneumoniae , Chlamydophila pneumoniae , influenza A virus (A/NewCal/20/99, A/Brisbane/10/07, A/NY/02/11), influenza B virus (B/Florida/02/06), rhinovirus, and respiratory syncytial virus A. SARS-CoV-2 cross-reactivity was evaluated by using known SARS-CoV-2-positive samples and Exact Diagnostics SARS-CoV-2 standard control material (Exact Diagnostics, Fort Worth, TX, USA). .. Nucleic acid, including internal positive control DNA (Exogenous Internal Positive Control Reagents, ThermoFisher, Waltham, MA, USA), was isolated on Qiagen EZ1 Advanced XL platform using the DNA Tissue Kit (Qiagen, Hilden, Germany) and subjected to real-time PCR analysis on an ABI 7500 real-time PCR system (ThermoFisher, Waltham, MA, USA).

    Control:

    Article Title: Development and Validation of a Multiplex Real-Time PCR Assay for Detection and Quantification of Streptococcus pneumoniae in Pediatric Respiratory Samples
    Article Snippet: For cross-reactivity studies against Streptococcus. pseudopneumoniae , solutions in sterile water were prepared from plated media of ATCC ® strain BAA-960 ranging in concentration from 0.5 to 2.0 McFarland standard. .. The NATtrol Respiratory Verification Panel 2 (ZeptoMetrix, Buffalo, NY) was used for cross-reactivity studies of molecular material against Mycoplasma pneumoniae, Chlamydophila pneumoniae , influenza A virus (A/NewCal/20/99, A/Brisbane/10/07, A/NY/02/11), influenza B virus (B/Florida/02/06), rhinovirus, and respiratory syncytial virus A. SARS-CoV-2 cross-reactivity was evaluated by using known SARS-CoV-2-positive samples and Exact Diagnostics SARS-CoV-2 standard control material (Exact Diagnostics, Fort Worth, TX, USA). .. Nucleic acid, including internal positive control DNA (ThermoFisher, Waltham, MA, USA), was isolated on Qiagen EZ1 Advanced XL platform using the DNA Tissue Kit (Qiagen, Hilden, Germany) and subjected to real-time PCR analysis on an ABI 7500 real-time PCR system (ThermoFisher, Waltham, MA, USA).

    Article Title: Development and validation of a multiplex real-time PCR assay for detection and quantification of Streptococcus pneumoniae in pediatric respiratory samples
    Article Snippet: For cross-reactivity studies against Streptococcus pseudopneumoniae , solutions in sterile water were prepared from plated media of ATCC strain BAA-960 ranging in concentration from 0.5 to 2.0 McFarland standard. .. The NATtrol Respiratory Verification Panel 2 (ZeptoMetrix, Buffalo, NY, USA) was used for cross-reactivity studies of molecular material against Mycoplasma pneumoniae , Chlamydophila pneumoniae , influenza A virus (A/NewCal/20/99, A/Brisbane/10/07, A/NY/02/11), influenza B virus (B/Florida/02/06), rhinovirus, and respiratory syncytial virus A. SARS-CoV-2 cross-reactivity was evaluated by using known SARS-CoV-2-positive samples and Exact Diagnostics SARS-CoV-2 standard control material (Exact Diagnostics, Fort Worth, TX, USA). .. Nucleic acid, including internal positive control DNA (Exogenous Internal Positive Control Reagents, ThermoFisher, Waltham, MA, USA), was isolated on Qiagen EZ1 Advanced XL platform using the DNA Tissue Kit (Qiagen, Hilden, Germany) and subjected to real-time PCR analysis on an ABI 7500 real-time PCR system (ThermoFisher, Waltham, MA, USA).



    Similar Products

    93
    ZeptoMetrix corporation nattrol respiratory verification panel 2 1
    Nattrol Respiratory Verification Panel 2 1, supplied by ZeptoMetrix corporation, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nattrol+respiratory+verification+panel+2/NATtrol+Respiratory+Verification+Panel/pmc12844171-237-3-8
    Average 93 stars, based on 1 article reviews
    nattrol respiratory verification panel 2 1 - by Bioz Stars, 2026-10
    93/100 stars
      Buy from Supplier

    93
    ZeptoMetrix corporation nattrol respiratory verification panel 2
    Nattrol Respiratory Verification Panel 2, supplied by ZeptoMetrix corporation, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nattrol+respiratory+verification+panel+2/NATtrol+Respiratory+Verification+Panel/pm37937989-79-1-6
    Average 93 stars, based on 1 article reviews
    nattrol respiratory verification panel 2 - by Bioz Stars, 2026-10
    93/100 stars
      Buy from Supplier

    94
    ZeptoMetrix corporation nattrol tm respiratory verification panel 2
    Nattrol Tm Respiratory Verification Panel 2, supplied by ZeptoMetrix corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/nattrol+respiratory+verification+panel+2/Respiratory+Verification+Panel/pm33271166-28-7-13
    Average 94 stars, based on 1 article reviews
    nattrol tm respiratory verification panel 2 - by Bioz Stars, 2026-10
    94/100 stars
      Buy from Supplier

    Image Search Results